Stand for PUE C32 / PUE 7.1 terminal - mild steel version (WX-004-0272)
A stand, based on a tripod for supporting scale's indicator installed on a cable PUE C32 / PUE 7.1. Mild steel version available.
WLY 2/D2
But also parts counting, checkweighing, percent weighing, animal weighing, formulations and differential weighing. The power of WLY’s working mods.
Request a quoteDownload the datasheet
Fast and accurate weight determination thanks to the duo: the WLY multifunction balance and the PUE7 weighing terminal. Ease of operation and maximum automation of the weighing process.
But also parts counting, checkweighing, percent weighing, animal weighing, formulations and differential weighing. The power of WLY’s working mods.
Barcode scanners, receipt printers, label printers, RFID readers, PC equipment or an additional weighing platform – thanks to multipurpose software, WLY balance can work with all of them. You can find all accessories in our regular offer. And if you have questions about compatibility, our experts will help you.
With WLY you will Do It Yourself:
This balance is the result of a combination of our experience and true precision.

You can. With Label Editor software, you will generate:
THBR 2.0 System
Cooperation with THBR 2.0 System for ambient conditions monitoring.
Stainless Steel in RADWAG products
Learn about the use and maintenance of stainless steel products:
Stainless Steel in RADWAG products. Standard and special applications

| Maximum capacity [Max] | 2 kg |
|---|---|
| Minimum load | - |
| Readability [d] | 0,01 g |
| Verification unit [e] | - |
| Tare range | -2 kg |
| Repeatability | 0,03 g |
| Linearity | ±0,03 g |
| Stabilization time | 3 s |
| Adjustment | external |
| OIML Class | - |
| Leveling system | manual |
|---|---|
| Display | 5,7” Resistive Color Touchscreen |
| Weighing pan dimensions | 195×195 mm |
| Packaging dimensions W x D x H | 530×310×150 mm |
| Net weight | 3,7 kg |
| Gross weight | 4,4 kg |
| Protection class | IP 43 |
|---|
| Communication interface | 2×RS232, 2×USB-A, Ethernet, 4 IN / 4 OUT (digital), Wi-Fi ® |
|---|
| Power supply | Adapter: 100 – 240V AC 50/60Hz 1A; 15V DC 2,4A Balance: 10 – 28V DC 1A max |
|---|
| Operating temperature | +15 – +30 °C |
|---|---|
| Storage temperature | -25 – +70 °C |
| Relative humidity | 10% – 85% RH no condensation |
Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph - load indicator. For industrial scales it is possible to use a control systems of dosing process.
Marking products with the right symbols contributes to quick and reliable identification. The balance/scale usually transfers product mass or product quantity to the label printer. The transferred value is printed with the following information: bar code, pictogram, content, address etc. In laboratory the labelling is performed in a semi-automatic mode, for industry in an automatic one (dynamic scales).

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly exceeded.
Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Function using mass measurement for determination of measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Function supporting the mixture making process, wherein the mixture contains various components. Formulation function usually uses the balance/scale database of components. Formulation serves for monitored checkweighing of every single component with a given tolerance. It is enriched with a set of individual settings.
Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g ± 5 g
Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
Differential weighing informs about mass variation a particular sample, wherein the said variation is a result of manufacturing processes.
"ALIBI" memory enables saving and storing up to 100000 measurements. Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
WX-016-0152 Audit Trail (PUE HY10)
WX-016-0201 Audit Trail (PUE 7.1, PUE 7.1P)
WX-016-0210 Audit Trail (WLY)
Audit Trail is a kind of a log where all modifications of balance settings, changes in database records and user activity are recorded. Audit Trail, for example, keeps record of previous and new modifications in databases and informs by whom and when they were introduced.
The Audit Trail Reader freeware allows users, upon connection with a balance, to display Audit Trail log and manage it by generating reports of various formats: pdf, xls, csv, html.
WX-016-0154 RES level: 0,1,2 (PUE HY10)
WX-016-0212 RES level: 0,1,2 (WLY, PUE71)
WX-016-0264 RES level: 0,1,2 (4Y, 5Y)
WX-016-0265 RES level: 0,1,2 (X2, X7)
WX-016-0292 RES level: 0,1,2 (PUE HX7)
WX-016-0293 RES level: 0,1,2 (PUE C32)
WX-016-0208 Workflow (PUE HY10)
WX-016-0213 Workflow (WLY)
WX-016-0214 Workflow (PUE 7.1/PUE 7.1P)
WX-016-0153 RDA (PUE HY10)
WX-016-0202 RDA (PUE 7.1, PUE 7.1P)
WX-016-0211 RDA (WLY)

A stand, based on a tripod for supporting scale's indicator installed on a cable PUE C32 / PUE 7.1. Mild steel version available.

R02 Label Editor is a proprietary application of RADWAG, which allows users to make labels forindustry scales, scales intended for EX area, PGC…

Enhance the functionality of your weighing system with the DP-6 module from RADWAG, a leader in precision weighing innovations. This advanced module…

The CK-02/4 is additional equipment for load cell based industrial scales. It can be used for:

The RADWAG RTP-RU80 is a modern receipt printer designed to work with laboratory and industrial scales. Equipped with RS232 and USB interfaces, it…

To be able to analyse and correct them in real time? After all, it is the key to increasing the efficiency of the production line! Our clients, the…


Cable with jack for plugging to a car lighter 12V (PUE C315).

LS2208 barcode scanner is a manual device designed for operation in adverse industrial conditions. It integrates with RADWAG terminals, PUE H315, PUE…
Additional WD-4/4 LCD display has been designed to connect with PUE 7 indicator via D-SUB 15 connector (male plug). The display is equipped with a…

To be able to analyse and correct them in real time? After all, it is the key to increasing the efficiency of the production line! Our clients, the…

enables collecting, presenting and carrying out statistical analysis of measurements sent from RADWAG scales to a computer. The software operates…
Instruments to quote
No instruments yet. An enquiry can be sent anyway: a specialist answers.