A unit of AKRIBIS One

XA 110.5Y.F

XA 110.5Y.F Analytical Balance

XA 5Y.F Analytical Balances are used in quality control processes, where accurate weighing of filters is used to assess filtration efficiency or to calculate the mass of particles retained by the filter. This task is made possible by a weighing pan for filters with which these balances are equipped in addition to the regular one.

Request a quoteDownload the datasheet

XA 110.5Y.F Analytical Balance

Overview

XA 110.5Y.F Analytical Balance for Filters

XA 5Y.F Analytical Balances are used in quality control processes, where accurate weighing of filters is used to assess filtration efficiency or to calculate the mass of particles retained by the filter. This task is made possible by a weighing pan for filters with which these balances are equipped in addition to the regular one.

Semi-automatic Leveling System

The devices also have a manually opened weighing chamber and use a semi-automatic levelling system. Semi-automatic levelling, the so-called LevelSENSING System, has a great advantage over the manual levelling, in the case of the former one the user is prompted in which direction to level the balance. This shortens the very process.

Do you need a balance that not only determines weight with impressive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages?

If so, learn about the functionality of the ELLIPSIS series of balances:

XA 110.5Y.F Analytical Balance

Digital Weighing Auditor

Ensures that your balance is ready for use. It enables air buoyancy compensation in real-time. What is more, it informs about the need for a balance inspection or a periodic audit of the balance’s accuracy and sensitivity.

10-Inch Display

Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history.

Uncompromising User Verification

For the first time ever, the balance will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, orany combination of these.

Ambient Light – one look and everything is clear

The color of the backlight will tell you about status, process results, procedures or alerts. Advanced methods of communication of the balance with the user provide efficiency, transparency and convenience in daily work.

XA 110.5Y.F Analytical Balance

Hotspot

Use the balance on any device connected to it. This can be a smartphone, tablet, or computer.

RFID

ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user.

Live Note – Note Down Your Conclusions

It’s the first time you can add a text memo to a measurement series or procedure report. These can be, for example, assumptions, reminders or questions that can be returned to at any time.

Handy Library

This is where a series of recent measurements or a report ready for digital signature, according to21 CFR Part 11, can be found.

Widgets

Prepared to display what you need most at any given moment.

Smart Min Weight

The balance displays whether the value of the weight you want to weigh is below or above the minimum weight threshold.

XA 110.5Y.F Analytical Balance

21 CFR Part 11

Do you work in the pharmaceutical industry? Do you need a digital signature?

We are offering the laboratory balance which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11.

–Full data security

Modbus TCP/IP

is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators.

A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds.

XA 110.5Y.F Analytical Balance

Two-point adjustment

Adjacency, which takes place at two measurement points instead of one, improves measurement precision over the full weighing range. And what does this mean for you? More accurate measurement.

Under-pan weighing

Weighing instruments purchased after 15th February 2023 will allow under-pan weighing at any time after the purchase. All you need to do is just to order a dedicated hook.

* RFID ISO/IEC 14443 Type A, 13.56 MHz

Stainless Steel in RADWAG products
Learn about the use and maintenance of stainless steel products:
Stainless Steel in RADWAG products. Standard and special applications

XA 110.5Y.F Analytical Balance

Metrological parameters

Maximum capacity [Max]110 g
Minimum load1 mg
Readability [d]0,01 mg
Verification unit [e]1 mg
Tare range-110 mg
Minimum weight (USP)14 mg
Minimum weight (U=1%, k=2)1,4 mg
Standard repeatability [Max]0,02 mg
Standard repeatability [5% Max]0,007 mg
Permissible repeatability [Max]0,03 mg
Permissible repeatability [5% Max]0,01 mg
Linearity±0,06 mg
Eccentric load deviation0,06 mg
Sensitivity time drift1×10⁻⁶/Year×Rt
Stabilization time5 s (30 s for filters)
Adjustmentinternal (automatic)
OIML ClassI

Physical parameters

Leveling systemsemi-automatic – LevelSENSING
Display10″ graphic colour touchscreen
Weighing chamber doorsmanual
Delivery componentsAnalytical Balance, weighing pan, weighing pan for filters, weighing pan shield, centring ring, bottom cover, brush, fabric dust cover, power supply.
Weighing pan dimensions210×254 mm for filters + ø90 mm open-work pan + ø85 mm standard pan (option)
Packaging dimensions W x D x H865×510×690 mm
Net weight13 kg
Gross weight24 kg

Construction

Protection classIP 43

Communication interface

Communication interface2×USB-A, USB-C, RS 232 (COM3), HDMI, Ethernet, Wi-Fi ® , Hotspot

Electrical parameters

Power supplyAdapter: 100 – 240V AC 50/60Hz 1A Max; 15V DC 2,4A Balance: 12 – 15V DC 1,4A max; 9 – 17W*

Ambient conditions

Operating temperature+10 – +50 °C

Functions

Autotest

Diagnostic function aiming at metrological parameters determination (repeatability), the parameters are determined for the actual conditions of use. When speaking of repeatability it may be also used for weighing time optimization. Autotest is operated in an automatic mode thus operator’s time is saved.

Dosing

Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph - load indicator. For industrial scales it is possible to use a control systems of dosing process.

XA 110.5Y.F Analytical Balance

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly exceeded.

Parts counting

Function using mass measurement for determination of measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.

XA 110.5Y.F Analytical Balance

Formulation

Function supporting the mixture making process, wherein the mixture contains various components. Formulation function usually uses the balance/scale database of components. Formulation serves for monitored checkweighing of every single component with a given tolerance. It is enriched with a set of individual settings.

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.

Checkweighing

Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g ± 5 g

XA 110.5Y.F Analytical Balance

IR sensors

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.

Under-pan weighing

The solution enables weighing with use of a stand, which is advisable for loads of non-standard shapes and dimensions and those that generate magnetic field.

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.

XA 110.5Y.F Analytical Balance

Air density correction

Function performing correction of mass measurement indication, wherein the air density is taken into account. It is used in balances with reading unit < 0,01 mg.

Differential weighing

Differential weighing informs about mass variation a particular sample, wherein the said variation is a result of manufacturing processes.

Differential weighing is often applied in product control process, for which reference product parameters have been specified in order to be used as a source of comparison for the whole series.
Insuchcasestandard deviation is the information which tells about quality and completeness of a final product. For systems based on a feed-back technique such information may be used by control units.

XA 110.5Y.F Analytical Balance

Ambient conditions monitoring

The possibility of cooperation with the THBR 2.0 system

Replaceable unit

Weight function to change the weight unit.

Statistical Quality Control

Statistical control for determination of basic statistical criteria: maximum, minimum, standard deviation, mean values for each batch, etc.

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements. Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.

Wi-Fi ®

Thanks to wireless communication between the computer and a balance, it is possible to use a balance inside a laminar flow hood and a fume cupboard.

XA 110.5Y.F Analytical Balance

Additional modules

RES Radwag Extended SI Module

WX-016-0154 RES level: 0,1,2 (PUE HY10)

WX-016-0212 RES level: 0,1,2 (WLY, PUE71)

WX-016-0264 RES level: 0,1,2 (4Y, 5Y)

WX-016-0265 RES level: 0,1,2 (X2, X7)

WX-016-0292 RES level: 0,1,2 (PUE HX7)

WX-016-0293 RES level: 0,1,2 (PUE C32)

21 CFR Part 11 Compliance Module

WX-001-0133 CFR 21 (4Y, 5Y, CY10)

WX-001-0187 CFR 21 (X2, X7)

The module includes "Audit Trail".

Audit Trail is a kind of a log where all modifications of balance settings, changes in database records and user activity are recorded. Audit Trail, for example, keeps record of previous and new modifications in databases and informs by whom and when they were introduced. This log allows the administrator to track and find out who logged in, when, who signed a document or who used invalid password.

The Audit Trail Reader freeware allows users, upon connection with a balance, to display Audit Trail log and manage it by generating reports of various formats: pdf, xls, csv, html.

310 ELLIPSIS – Scan or Tap to Log In

4Y Balances: Video-Guidance and an on-screen manuals

4y series - Ultra-microbalances and microbalances

5Y Balance and Barcode Scanner – Easy Connection

5Y Functions: Animal Weighing

5Y Functions: Checkweighing

Documents

  • LS 2208

    LS2208 Barcode Scanner

    LS2208 barcode scanner is a manual device designed for operation in adverse industrial conditions. It integrates with RADWAG terminals, PUE H315, PUE…

  • R-LAB

    R-Lab

    enables collecting, presenting and carrying out statistical analysis of measurements sent from RADWAG scales to a computer. The software operates…

  • DJ-04

    DJ-04 Antistatic Ionizer

    Antistatic ionizer is used to remove overflow of mainly plus ions, and also minus ions from the load and elements of a balance and the environment…

  • SAL/C

    SAL/C Laboratory Antivibration Table

    The antivibration table has been designed to eliminate ground vibrations during the operation of laboratory equipment such as microbalances…

  • WX-010-0038

    E2R Weighing Records (WX-010-0038)

    To be able to analyse and correct them in real time? After all, it is the key to increasing the efficiency of the production line! Our clients, the…

  • THB W

    THB W Liquid Temperature Sensor

    THB W can be used e.g. on pipettes calibration workstation, to measure water temperature in gravimetric method, which is done in order to determine…

Write on WhatsApp