XA 21.5Y.M.A.P
XA 5Y.M.A.P Microbalances are designed to calibrate single-channel pipettes from 0.5 µl. Pipette calibration means checking whether the pipette draws as much as it should, and thus whether the measurement result is within the permissible error.
Request a quoteDownload the datasheet
XA 5Y.M.A.P Microbalances are designed to calibrate single-channel pipettes from 0.5 µl. Pipette calibration means checking whether the pipette draws as much as it should, and thus whether the measurement result is within the permissible error. XA 5Y.M.A.P Microbalances have the same features as the XA 5Y.M.A Microbalances, but since they are dedicated to pipette calibration, they are additionally equipped with an automatic pipette calibration adapter, including a pipette calibration adapter, an evaporation ring and a glass vessel (we have listed all the components of the calibration adapter below, next to the datasheet).
The XA 5Y.M.A.P Microbalances has a built-in antistatic ionizer and an automatically opened weighing chamber. The built-in antistatic ionizer neutralizes the electrostatic charge of the sample during each weighing procedure, that is, each time the chamber is opened. The automatically opened weighing chamber is controlled by gestures, i.e. non-contact.
Do you need a balance that not only determines weight with impressive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages?
If so, learn about the functionality of the ELLIPSIS series of balances:

Ensures that your balance is ready for use. It enables air buoyancy compensation in real-time. What is more, it informs about the need for a balance inspection or a periodic audit of the balance’s accuracy and sensitivity.
Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs,statuses, notes, handy measurement history.
The light colour will tell you about status, process results, procedures, or alerts.
For the first time ever, the balance will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, orany combination of these.

Use the balance on any device connected to it. This can be a smartphone, tablet, or computer.
It’s the first time you can add a text memo to a measurement series or procedure report. These can be, for example, assumptions, reminders or questions that can be returned to at any time.
ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user.
This is where a series of recent measurements or a report ready for digital signature, according to21 CFR Part 11, can be found.
Prepared to display what you need most at any given moment.
The balance displays whether the value of the weight you want to weigh is below or above the minimum weight threshold.

Instead of manually leveling your scale - level it automatically.
Do you work in the pharmaceutical industry? Do you need a digital signature?
–Full data security
–Electronic signatures
–Validations
–Electronic records
–Audit trails
is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators.
A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds.
Adjacency, which takes place at two measurement points instead of one, improves measurement precision over the full weighing range. And what does this mean for you? More accurate measurement.
* RFID ISO/IEC 14443 Type A, 13.56 MHz

| Maximum capacity [Max] | 21 g |
|---|---|
| Minimum load | 0,1 mg |
| Readability [d] | 1 µg |
| Verification unit [e] | 1 mg |
| Tare range | -21 g |
| Minimum weight (USP) | 2,6 mg |
| Minimum weight (U=1%, k=2) | 0,26 mg |
| Standard repeatability [Max] | 3,5 µg |
| Standard repeatability [5% Max] | 1,3 µg |
| Permissible repeatability [Max] | 5 µg |
| Permissible repeatability [5% Max] | 2 µg |
| Linearity | ±9 µg |
| Eccentric load deviation | 15 µg |
| Sensitivity time drift | 1×10⁻⁶/Year×Rt |
| Stabilization time | ~ 3,5 s |
| Adjustment | internal (automatic) |
| OIML Class | I |
| Leveling system | automatic – Reflex Level System |
|---|---|
| Display | 10″ graphic colour touchscreen |
| Weighing chamber doors | automatic |
| Delivery components | Microbalance with an ionizer, weighing pan, weighing pan shield, power supply, automatic pipette calibration adapter: (base, bottom ring, glass vessel, pipette calibration adapter, evaporation ring, weighing pan, glass lid, mechanical closing cover, protecting screw), brush, fabric dust cover. |
| Weighing chamber dimensions | 199×170×217 mm |
| Capacity | 11 ml |
| Weighing pan dimensions | ø26 mm |
| Packaging dimensions W x D x H | 750×492×595 mm |
| Net weight | 16 kg |
| Gross weight | 20 kg |
| Protection class | IP 43 |
|---|
| Communication interface | 2×USB-A, USB-C, RS 232 (COM3), HDMI, Ethernet, Wi-Fi ® , Hotspot |
|---|
| Operating temperature | +10 – +40 °C |
|---|---|
| Operating temperature change rate | ±0,3 °C / 1 h (±1 °C / 8 h) |
| Relative humidity | 40% – 80% |
| Relative humidity change rate | ±1% / h (±4% / 8 h) |
Diagnostic function aiming at metrological parameters determination (repeatability), the parameters are determined for the actual conditions of use. When speaking of repeatability it may be also used for weighing time optimization. Autotest is operated in an automatic mode thus operator’s time is saved.
Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly exceeded.

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.

Function verifying correctness of piston pipettes functioning, the verification is performed via gravimetric measurement of the excreted liquid. Pipettes calibration may be either a stand-alone module or it may be operated
Function performing correction of mass measurement indication, wherein the air density is taken into account. It is used in balances with reading unit < 0,01 mg.
Automatic side panes opened via touch-free IR sensors.
Dual range analytical balances can be equipped with much more precise measuring range but only in very limited part of max capacity and only from zero load. A new technology introduced by RADWAG allows for moving this limited range till max capacity of the balance is reached. Such solution has been named as: Moveable range.

Differential weighing informs about mass variation a particular sample, wherein the said variation is a result of manufacturing processes.
Differential weighing is often applied in product control process, for which reference product parameters have been specified in order to be used as a source of comparison for the whole series.
Insuchcasestandard deviation is the information which tells about quality and completeness of a final product. For systems based on a feed-back technique such information may be used by control units.
The possibility of cooperation with the THBR 2.0 system
Weight function to change the weight unit.
Statistical control for determination of basic statistical criteria: maximum, minimum, standard deviation, mean values for each batch, etc.

"ALIBI" memory enables saving and storing up to 100000 measurements. Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Thanks to wireless communication between the computer and a balance, it is possible to use a balance inside a laminar flow hood and a fume cupboard.

WX-016-0154 RES level: 0,1,2 (PUE HY10)
WX-016-0212 RES level: 0,1,2 (WLY, PUE71)
WX-016-0264 RES level: 0,1,2 (4Y, 5Y)
WX-016-0265 RES level: 0,1,2 (X2, X7)
WX-016-0292 RES level: 0,1,2 (PUE HX7)
WX-016-0293 RES level: 0,1,2 (PUE C32)
WX-001-0133 CFR 21 (4Y, 5Y, CY10)
WX-001-0187 CFR 21 (X2, X7)
The module includes "Audit Trail".
Audit Trail is a kind of a log where all modifications of balance settings, changes in database records and user activity are recorded. Audit Trail, for example, keeps record of previous and new modifications in databases and informs by whom and when they were introduced. This log allows the administrator to track and find out who logged in, when, who signed a document or who used invalid password.
The Audit Trail Reader freeware allows users, upon connection with a balance, to display Audit Trail log and manage it by generating reports of various formats: pdf, xls, csv, html.

PIPETTES Extended Module is designed for checking and calibrating single-channel pipettes according to ISO 8655.
We have implemented the module in the 5Y terminal as an optional feature that you can activate. If you choose to do so, you will receive a lifetime license.
The PIPETTES Extended Module creates its own web page (works together with the Web Editor application) and is based on the PIPETTES software. The Web Editor is used to manage databases, edit pipette calibration orders and generate reports on calibration with the use of a web browser.


The table has been designed to eliminate ground vibrations during the operation of laboratory equipment such as microbalances, analytical balances…

The antivibration table has been designed to eliminate floor vibrations during the operation of PLUS series laboratory balances. It consists of two…

The antivibration table has been designed to eliminate floor vibrations during the operation of PLUS series laboratory balances. It consists of two…

R02 Label Editor is a proprietary application of RADWAG, which allows users to make labels forindustry scales, scales intended for EX area, PGC…

THB sensor is a device measuring ambient conditions, it cooperates with:

The 21 CFR Part 11 Compliance Module is a solution especially useful for those users who are obliged to conform to provisions of 21 CFR Part 11 and…

The professional weighing workstation is intended for microbalances and analytical balances. It is equipped with two lockers for a computer and an…

enables collecting, presenting and carrying out statistical analysis of measurements sent from RADWAG scales to a computer. The software operates…

LS2208 barcode scanner is a manual device designed for operation in adverse industrial conditions. It integrates with RADWAG terminals, PUE H315, PUE…

The RADWAG RTP-RU80 is a modern receipt printer designed to work with laboratory and industrial scales. Equipped with RS232 and USB interfaces, it…

Antistatic ionizer is used to remove overflow of mainly plus ions, and also minus ions from the load and elements of a balance and the environment…

To be able to analyse and correct them in real time? After all, it is the key to increasing the efficiency of the production line! Our clients, the…
Instruments to quote
No instruments yet. An enquiry can be sent anyway: a specialist answers.