A unit of AKRIBIS One

Model-17402

Gallium Fixed Point Apparatus

Model 17402B Gallium Apparatus is not an adaptation from general purpose equipment, but is designed specifically to realize and maintain the Gallium Cell on the melt plateau, for calibration of thermometers on the International Temperature Scale of 1990.

Request a quoteDownload the datasheet

Gallium Fixed Point Apparatus

Features

  • Simple, automatic and safe operation
  • Reproducibility day-to-day of ±0.000025°C
  • 20 years of world-wide deliveries without breakage
  • 99.999999% purity
Gallium Fixed Point Apparatus

Description

The apparatus will permit the gallium to melt coaxially over 12 to 16 hours. It is uniquely designed to also freeze the cell from the bottom up, which eliminates the danger of damage due to the expansion of gallium during freezing.

  1. Model 17401 Gallium Cell may be used in a well controlled bath without the need for the thermal environment provided by Model 17402B Gallium Apparatus. However, because of the advantages of automatic operation, convenience and cell protection, Isotech recommend the use of the Model 17402B environment in most cases.
  2. No external connections other than power are required.
  3. A completely automatic electronic control system provides a precise means for realization and maintenance of the plateau. The Apparatus can be turned on by a timer an hour before the laboratory day begins, the plateau utilized throughout the working day and the system recycled overnight. A thermal sink is provided which forces the gallium to refreeze upwards from the bottom (gallium expands when it freezes, requiring a specific freeze orientation to avoid rupturing the cell).
  4. Confidence is a major requirement in a standard. The Isothermal Gallium Cell and Apparatus have a long (20 year) history and have been successfully used in most National and Primary Laboratories world-wide. This is one of the main reasons for choosing the Isothermal Cell and Apparatus.
  5. The Cell and Apparatus are manufactured to the strict requirements of BS 5750 and ISO 9000. Each finished unit becomes part of the Isotech UKAS working Calibration Laboratory for two weeks or more, during which use the control circuits are set and checked for optimum performance. It is released only when Isotech are entirely satisfied with its performance.
Gallium Fixed Point Apparatus

Specifications

ModelITL-M-17402B cell apparatus
Temperature Range29.7646°C
Uncertainty0.25mK (with cell)
Ambient Limits15°C to 28°C
Cycle TimeWith cell at 20°C, time to plateau is 1 hour maximum. Recycling, including freezing the cell is typically 3 to 4 hours.
Plateau DurationNot less than 12 hours under specified ambient conditions; 16 hours typical
Power75 Watts typical 100-130 or 208-240 Vac* 50/60Hz (*fields changeable)
DimensionsHeight 429mm, Width 259mm, Depth 181mm, Weight 8.4kg
How to orderITL-M-17402B Gallium Apparatus (without cell), please specify voltage required. Model Gallium Cell ITL-M-17401

Documents

  • Medium-Temperature-Furnace

    Medium Temperature Furnace

    Whilst heat pipe furnaces offer the ideal environment to melt and freeze ITS-90 Fixed Points the temperature range is limited by fluid that flows…

  • HTSPRT-96178

    Isotech Model 96178 HTSPRT

    Isotech has produced over 200 high temperature thermometers which have been sold world-wide for use up to the silver point. As a consequence of our…

  • Annealing-Furnace

    Annealing Furnace

    The Annealing Furnace, model 414, is designed to heat, anneal and cool Standard Platinum Resistance Thermometers (SPRTs) prior to calibration. The…

  • Low-Temperature-Furnace

    Low Temperature Furnace

    The Isotech Low Temperature Fixed Point Furnace is designed specifically to realize and maintain the freeze plateaux of Isotech Indium, Tin and Zinc…

  • Mercury-Triple-Point-Cell

    Mercury Triple Point Cell

    The Isotech Mercury Cell Model is constructed in a rugged, sealed stainless steel enclosure allowing the triple point of -38.8344°C to be realized…

  • ISOTowers-Series

    ISOTowers

    The most accurately defined temperatures are those defining points (fixed points) of ITS-90.

  • Mercury-Triple-Point-Apparatus

    Mercury Triple Point Apparatus

    The Isotech Model ITL-M-17725 apparatus is a self-contained, mechanically-refrigerated, system with a main well to house one mercury cell and two…

  • Gallium-Fixed-Point-Cell

    Gallium Fixed Point Cell

    Second only to the Water Triple Point and in many ways, because of its ease of use and purity, superior to it, is the Gallium Melt Point. At…