Indigo80 Handheld Indicator
The latest addition to the Indigo family of transmitters and probes, the Indigo80 is a compact, handheld indicator and data logger. Ideal for field…
Measurement
Fast and accurate measurements for low-humidity industrial processes down to -80 °C Td/f
Content from Vaisala · retrieved on View the original source

The drier the condition, the more challenging it is to measure
Vaisala keeps pushing the boundaries of measuring humidity lower and drier
The temperature at which water vapor condenses into liquid. The benchmark for dryness.
Typical quality level for compressed air (ISO 8573-1 Class 2) and drying systems. Antarctica, the driest place on Earth, naturally.
Extremely dry gas environment. Typical desiccant -based drying target. Electronics, cleanrooms, dry rooms, PET bottles, specialty coating, adhesives.
ISO 8573-1 Class 1 compressed air limit for critical applications such as semiconductor manufacturing. Dew point conditions on Mars, monitored using Vaisala sensors.
Learn how to avoid multi-degree conversion errors in low-humidity measurements Vaisala's recommendations
Ultra-dry gas environment. Aerospace, satellite, pharmaceutical, semiconductor, battery, R&D.Reach new extremes with Vaisala's new Dew Point Transmitter DMT153.
In many industrial manufacturing processes, precise control of humidity, or trace moisture, is essential to maintain product quality, ensure equipment reliability, and support safe and efficient operations.
Low-humidity environments, defined here as <10 %rh, require measurement technologies that remain accurate and responsive under demanding conditions.
Dew point, the temperature at which water vapor begins to condense, is the benchmark of process dryness as it is a direct indicator of the absolute moisture content in air or gas.
Unlike relative humidity, which depends on temperature, dew point remains consistent and provides a stable metric for dry environments and critical processes.
Vaisala provides compact dew point probes that deliver accurate, stable, and fast-responding measurements.
Their rapid response enables the timely detection of moisture changes, helping operators maintain control of trace moisture-sensitive processes, minimize contamination risk, and avoid unplanned downtime or system failures.
Why wait? When humidity changes are detected instantly inline, you stay in control, protect sensitive processes, and avoid contamination, downtime, and system failures.
Mix and match measurement parameters and probes to fit your process
Reliable even with condensation, stable despite chemical exposure, and auto-calibration optimizes the measurement stability in dry environments.
Dew point is measured by determining the moisture content of air or gas and converting it to the temperature at which condensation begins.
Vaisala dew point/frost point measurement is based on revolutionary capacitive thin-film humidity technology, sensing relative humidity and ultra-stable platinum-based temperature sensors to determine dew point/frost point calculated from these measurements.
There are different measurement principles available, such as advanced humidity sensors that infer dew point from relative humidity and temperature, and chilled mirror instruments that observe condensation.
Accurate dew point measurement depends on:
Review how Vaisala's dew point probe compares to CRDS' (Cavity Ring-Down Spectrometer)
and Chilled mirror transmitters in the most demanding operating environments, such as
rechargeable battery and semiconductor manufacturing.
Vaisala’s dew point probeCRDSChilled mirror transmitterTd measurement
range*-80 °C…+20 °C-100 °C…-50 °C -70 °C…+20 °C In-situ measurementYesNo, requires sampling and a large pressure differenceNo, requires samplingTd accuracy in
laboratory conditions* +/-2 °C+/-0.2 °C+/-0.2 °CPressure range* 1…50 bar 1…5 bar~ 1 bar onlyDependency of
atmospheric
conditionsNot dependentDependent. Stable atmospheric conditions required. Sampling might generate errors in non-laboratory
environment. Dependent. Minimum dew point will raise if the ambient temperature increases. Sampling might generate errors in non-laboratory environment.Response time* MinutesTens of minutesHoursSensitivityHighLow (cannot detect quick changes, averaging measurement)Low (cannot detect quick changes, averaging
measurement)Size Small and light. Fits easily to multiple locations Mid size, about 10 kgFrom big and heavy to mid sizeOperator to provide
regular serviceNot requiredNot requiredRequiredComponents requiring
serviceNot requiredNot required, if in clean environmentRequired (e.g., Peltier)Local calibration/
support availableYesUnlikelyUnlikelyDependency of
background gasesMinorPotentially strongPotentially crucial
* Typical values in battery and semiconductor manufacturing
It's particularly important to:
It's particularly important to:
It's particularly important to:
Vaisala recommends regular intervals specified in each instrument’s datasheet; however, the timing of the next calibration is ultimately up to the end user's quality requirements and operating conditions.
Vaisala instruments are always delivered with a calibration certificate.
Key considerations include:
Environmental factors that may require more frequent calibration include:
With Vaisala as your calibration partner for dew point measurement, you can save energy and improve the cost-efficiency of your processes. If you are in doubt as to how often your instruments need to be calibrated to maintain measurement reliability and accuracy, contact us.

In theory yes, but it is impractical and expensive. Vaisala's instruments are optimized for certain dew point levels, and the selection covers a variety of instruments.
Not always. If you need accurate measurements at extremely low dew points, then yes, a lower-range sensor is beneficial. But for moderately dry conditions like -40…-60 °C Td/f, choosing an instrument that goes down to -80 °C Td/f will not improve performance.
The best sensor is the one that matches your process, not the one that measures the driest possible conditions.
It depends on the sensor technology. Vaisala DRYCAP sensors do not lose accuracy when stored in typical indoor humidity, and they can even be exposed to liquid water and still recover fully.
A sampling system is relevant when one or more of the following apply:
Since its launch, the DRYCAP product family has expanded to a wide range of uses, from drying processes to compressed air and dry chambers. The DRYCAP sensor is especially valued for its reliable performance in extremely dry, hot environments, driving continuously growing demand.
All of Vaisala's humidity and temperature instruments can output dew point.
Measuring dew point allows for predictive maintenance, process optimization, and regulatory compliance across many sectors
Ensure the highest quality and performance of rechargeable batteries with accurate moisture and liquid concentration measurements
Trusted measurements for pressure, temperature, humidity, and liquid concentration measurements for increased yield, safety, and best-performing products.
From research labs to production areas and warehouses, Vaisala delivers precision and compliance at every stage of your GxP-regulated operations. Our high-performance data loggers, smart probes, transmitters, inline refractometers, and monitoring software are engineered for reliability and built to meet global regulatory standards.
Measuring small changes in dew point temperature can add to immeasurable results in compressed air quality.

The latest addition to the Indigo family of transmitters and probes, the Indigo80 is a compact, handheld indicator and data logger. Ideal for field…

Vaisala's PEROXCAP® vaporized hydrogen peroxide probes for simple, accurate, and effective bio-decontamination
1 instruments
Vaisala solutions for carbon capture, utilization and storage
1 instruments

Measuring small changes in dew point temperature can add to immeasurable results in compressed air quality
1 instruments



Continuous temperature and humidity monitoring in food, beverage and pharmaceutical storage facilities and warehouses, with cold chain traceability…
1 instruments


Measure dew point in blanketing atmosphere with Vaisala DRYCAP® sensor technology
1 instruments
Trusted measurements for pressure, temperature, humidity, and liquid concentration measurements for increased yield, safety, and best-performing…
1 instruments
Why dew point defines compressed air quality, how it is measured at line pressure or with a sampling cell, and what the ISO 8573-1 standard requires.
Why the furnace atmosphere's moisture defines heat treatment quality, which dew point ranges are controlled depending on the process, and how to…

Sampling is needed when direct measurement of the air is undesirable or is simply not feasible. This may be due to a high process temperature, the…

The most common issues with dew point sensors in compressed air are usually centered on the following:

This paper discusses the following topics in order to help in selecting the right humidity instrument:

In industrial applications like secondary battery manufacturing, controlling humidity is critical to ensuring product quality and preventing defects…
A specialist replies with the solution, the instrument and the service that fit.
Instruments to quote
No instruments yet. An enquiry can be sent anyway: a specialist answers.