Humidity Fundamentals, Part 1: Key Concepts
What relative humidity, dew point, absolute humidity and mixing ratio are, how temperature and pressure distort the reading, and why dew point is…
Technical note
Industrial wastewater can be revealing – as well as showing whether wastewater content is compliant with environmental regulations, it can also show how efficiently a plant is running. Inline measurement gives producers accurate real-time information on wastewater content, helping to prevent product loss and organic overload.
The food and beverage industries consume large amounts of water and generate wastewater with a high organic load, including oils and fats, sugars, alcohols, and proteins. Strict regulations control the release of these organic pollutants into the environment. This is because they contribute to wastewater having a higher level of total dissolved solids (TDS) and correlate closely with higher chemical oxygen demand (COD) and biological oxygen demand (BOD).
In basic terms, this means the decomposition process of the organic material is consuming the oxygen contained in the water – which can have severe consequences for the surrounding environment. Detecting rising levels of TDS with wastewater and effluent monitoring can help producers prevent product loss, reduce treatment load, avoid environmental fines, and improve sustainability performance.
Traditional wastewater sampling relies on periodic sample collection and laboratory tests. This only gives a snapshot of wastewater quality at the time the sample was taken – and getting the results takes time. By the time adjustments can be made to the process, the situation can be quite different to when the sample was taken.
Sampling can also miss short-term process issues, such as a spill from a mixing tank or an unexpected surge in organic load. By the time the lab results are ready, valuable product may have already been lost or spoiled.
Unlike snapshot sampling, inline refractometers provide continuous, real-time measurement of dissolved solids content in wastewater. This reveals any process anomalies almost as soon as they occur. The refractometer acts as an early warning system, detecting sudden spikes in refractive index (RI) that indicate higher TDS levels or increased concentration of organic material. This early warning helps to minimize product spills and maintain optimal loading to wastewater treatment plants.
In many plants, even short-term spikes in organic load can lead to thousands of euros in product losses, increased sludge handling, or unplanned treatment costs. Early detection of rising organic or contaminant load brings multiple operational and environmental advantages:
These benefits are well documented. Numerous studies show that real-time monitoring and control with a process refractometer provides valuable insights into TDS trends, helping wastewater treatment facilities keep key parameters such as COD and BOD within acceptable limits.
When you have continuous measurement data from inline refractometers, you can also integrate this data into your plant control system. Instead of waiting for lab results to confirm a problem, operators can see real-time data with alarms that flag any issues immediately – and automatic control actions that can handle changes in real-time. Over time, the measurement data builds into a valuable record that shows historical trends and enables predictive maintenance.
Turning wastewater data into actionable process intelligence also helps plants to optimize both water and material use. Real-time data helps ensure that wastewater is within permitted concentration limits, supporting water reuse and resource efficiency. This enables operators not only to react faster, but also to verify process improvements and track sustainability KPIs over time.
The Vaisala Polaris™ PR53 process refractometer provides reliable, continuous measurement of liquid concentration and total dissolved solids in wastewater or side streams. It works by measuring how light reflects at the interface between a prism and the process liquid, with a CCD camera detecting the critical angle of refraction to calculate the refractive index (RI). An integrated temperature sensor automatically compensates for process temperature variations.

With its hygienic, robust design, the Vaisala Polaris PR53 is ideal for the unique challenges of the food and beverage industries. There are no moving parts and the refractometer requires only minimal maintenance, with no recalibration. Because refractive RI can correlate with COD and total organic carbon (TOC) in some industrial applications, Vaisala Polaris refractometers can provide an effective, real-time surrogate measurement for monitoring changes in organic load in wastewater. However, the strength of this correlation depends on the specific composition of the wastewater, so site-specific calibration is recommended.
In wastewater or side stream processes, the Vaisala Polaris PR53 can be installed directly in the discharge lines to support real-time visibility and predictive wastewater management. Water of suitable quality can be recycled to reduce costs and water consumption, with real-time notification of product losses allowing for quick corrective actions. This helps producers to cut treatment costs, improve efficiency, and strengthen their sustainability performance.

What relative humidity, dew point, absolute humidity and mixing ratio are, how temperature and pressure distort the reading, and why dew point is…

How humidity behaves in real conditions, the three most common measurement problems, and two practical scenarios —heated air and compressed air—…
When to measure relative humidity vs. dew point, what high and low humidity demand, how temperature and pressure factor in, and when a warmed probe…

Cooling accounts for up to 40% of a data center's energy demand. This Vaisala guide explains how measurement accuracy cuts costs and risks, with a…
A specialist replies with the solution, the instrument and the service that fit.
Instruments to quote
No instruments yet. An enquiry can be sent anyway: a specialist answers.