
Vaporized Hydrogen Peroxide, Humidity and Temperature Measurement HPP270 Series
for bio-decontamination processes
Technical note
Inline Refractive Index Replaces Auto-titration in Qualifying H2O2 Concentration in CMP of Tungsten
Refractive index measurements have established themselves as the technique of choice for qualifying peroxide content in slurries for CMP of tungsten. Many emerging process flows use CMP as a critical tool for building circuit structures, dramatically increasing the number of CMP steps — and thus the number of opportunities for yield loss if slurry composition deviates from the specification. While auto-titration measurements can give extremely accurate results, they impose large capital equipment and ongoing maintenance costs and offer only discrete sampling at specified intervals. Refractive index, a continuous, non-slurry-consuming measurement, helps fabs identify slurry composition faults quickly, reducing the number of wafers at risk. Once calibrated to a specific slurry’s temperature/refractive index characteristics, refractive index measurements can determine the concentration of hydrogen peroxide in tungsten slurry to within ±0.03% by weight. Moreover, unlike conductivity probe tests, refractive index measurements can monitor slurry density, an indicator of settling and degradation of the slurry over time. Therefore, refractive index is used to qualify not only the final product for supply, but also to monitor batch to batch variation of incoming raw slurry and validate the blend addition steps.
...

for bio-decontamination processes

The latest addition to the Indigo family of transmitters and probes, the Indigo80 is a compact, handheld indicator and data logger. Ideal for field…

What relative humidity, dew point, absolute humidity and mixing ratio are, how temperature and pressure distort the reading, and why dew point is…

How humidity behaves in real conditions, the three most common measurement problems, and two practical scenarios —heated air and compressed air—…
When to measure relative humidity vs. dew point, what high and low humidity demand, how temperature and pressure factor in, and when a warmed probe…

Cooling accounts for up to 40% of a data center's energy demand. This Vaisala guide explains how measurement accuracy cuts costs and risks, with a…
A specialist replies with the solution, the instrument and the service that fit.
Instruments to quote
No instruments yet. An enquiry can be sent anyway: a specialist answers.